sponsor

sponsor

Slider

Videos

Vape Kits

Deals

Vape Tanks

Vape Mods

Giveaway

New Arrive

» » » » » » » Vaporesso Revenger Mini Kit User Manual


How to Use
1.Switch On/Off: Press the fire button 5 times in quick succession within 2 seconds to turn the device on. In the same way, the device will be powered off after 5 presses.

2.Vaping: Hold the fire button and inhale through the mouthpiece. Release the fire button and exhale.

3.Screen Display: After switching on, the OLED displays voltage resistance, battery level, temperature, output wattage etc. The display will change to Real Time Clock after 10 seconds if unused and the Real Time Clock will be shut off after 15 minutes if unused. Press “+” or “-“ or Mode button once and the screen will be lit with Real Time Clock display and press “+” or “-“ or Mode button again, the screen will be lit with main menu. Press the fire button at any time, the screen will be lit with main menu.

4.Automatic atomizer recognition: The mod will read the coil's resistance as soon as the connection is detected. It will also recognize coil type, when a kanthal coil is used, the mod will shift from TC to wattage mode automatically.

5.Adjustment buttons lock/unlock: For locking the buttons, please press fire button for 3 times. In the same way,press fire button for 3 times,the locked buttons can be unlocked.

6.Switch display mode: After unlocking the buttons, press the mode button for three seconds or quick press the mode button for 3 time to vaping modes selected menu and system setting menu.

7.Charging: It is with Quick Charge System and equalizing charge system. Simply plug in the USB cable to charge the battery, the OLED display current battery level (0%,20%, 50%, 80%, and 100%) and the Remaining Charging Time to get the battery fully charged. The Remaining Charging Time will be shown in every10 minutes. And the display will remain lit while charging.

8.Firmware update and customizing: Can be updated and customized through a simple software that can be downloaded directly from our website.
The software will be made to run on Windows systems and will be available in English. It will also include a “help”sections for urgent questions. The directions on how to use our software will be found on our website and Facebook page.

9.Adjustment of airflow: The bottom airflow system can be adjusted with slight twisting of the airflow ring.

10.Filling E-liquid: The Slide-n-Fill design only asks you to slide the top lip counter clockwise to the fullest extend. Fill in juice through the opening and slide the top back.

11.Changing Atomizer: Remove the base and unscrew the GT Cores and insert the new GT cores onto the base. Secure the base back in place. There are a variety of GT
cores available for NRG SE Tank series. Please select the GT Cores you desire.
12.Change LED Lighting Pattern: When in the “SYSTEM SET” menu,select the “LIGHT” submenu,there are 9 kinds of light display modes,the customized LED lighting pattern can be set in the custom mod.

How to Set the Mode
1) Smart VW mode:
As an advanced Variable Wattage mode, there are 3 levels of VW: VW-High stands for High; VW-Normal stands for Normal; VW-Soft stands for Soft. The default setting is Normal. VW(High/Normal/Soft) will guarantee your mod’ s ability to skillfully select the adequate average wattage for your atomizer, according to its resistance reading, automatically.

2) In CCW mode: While on VW mode, using the plus and minus buttons (Ramp up time and consequent performance) to confirm and to implement any modifications to the
wattage line; move on to the next bar with a press of the fire button.When all modifications are final set, please press the mode button to save and exit.

3) In TC-Ni/TC-Ti/TC-SS/TCR(M1, M2) Mode:
When set in VT-SS/VT-Ni/VT-TI mode, the device can separately support 316 Stainless, Steel Nickel 200,and Titanium coils. The OMNI Board 2.2 allows you to change the start up wattage under temperate control mode. The default wattage is 75W. You could also adjust the value of the coil within the given range.
In TCR (Temperature Coefficient of Resistance) mode, the device can support different temperature control coils within different TCR value ranges and you can set the TCR at different values within proper range.

The Setting of TCR Mode (M1,M2):
When set in TCR-M1,TCR-M2 mode
1. Press mode button to select the features setting among TCR Set, POWER Set ;
2. Press the up or down button to increase or decrease the TCR value and the power wattage according to the material of the coil you used;

Following are different TCR value ranges for different coils for your reference:

Note:
1.The TCR value in the sheet is 10 multiplied of the actual TCR.
2.Our total range of TCR value is 1-1000.

Adjust temperature: In TC-Ni/TC-Ti/TC-SS/TCR(M1,M2) mode, temperature can be adjusted from 100-315℃ or 200-600℉ by pressing up button or down button, up button to increase and down button to decrease. Each press of the up or down button will increase or decrease the temperature setting by 5℃ or 10℉. Long press up button or down button can rapidly increase or decrease temperature setting.

Automatic atomizer recognition: To achieve better temperature control effect, the mod will ask the user if the new atomizer is attached. " OLD LOAD: -, NEW LOAD: + " will appear on the display. If a new atomizer is attached, press " + ", the mod will read new resistance; if not, press " - ", the mod will read at locked resistance.

4) In CCT mode:
While on any VT mode, press the mode button to select CCT. using the plus and minus buttons (Ramp up time and consequent performance) to confirm and to implement any modifications to the temperature line; move on to the next bar with a press of the fire button.When all modifications are final set, please press the mode button to save and exit.

5) In Bypass mode:
Direct output voltage system is applied in Bypass mode. The higher the battery level is, the higher the output voltage is. When set in this mode, the device can support a coil whose resistance is within the range of 0.05-5ohm.

6) Smart ON/OFF:
As an advanced Variable Wattage mode, Smart VW could be switched on and off on the main manual and it does not impact the VW(H/N/S). Enter Smart ON/OFF and press Yes or NO to confirm.

7) Screen Timeout:
The default timeout setting is 10 seconds of main menu and then switch to Real Time Clock for another 15 minutes. The timeout setting could be adjusted from 3 seconds up to 60 minutes. Enter the Screen Timeout and adjust the time up or down as you wish. For example, if you choose 3 seconds, after 10 seconds of showing the main menu, the display will be showing 3 seconds of Real Time Clock.

8) Default:
You could reset to default setting by entering Default and pressing YES.

Protection Functions

  • USB Input Protection
  • Equalizing charge system
  • Low voltage protection
  • Output short circuit protection
  • Low resistance protection
  • Over-temperature protection
  • Overcurrent protection
  • Anti-loaded battery protection

«
Next
Newer Post
»
Previous
Older Post

No comments:

Leave a Reply